1. Definition of Abnormal and Protective Control
Abnormal and Protective Control is the control domain that detects abnormal conditions when a machine deviates from normal operating conditions, evaluates their impact and severity, and restricts, interrupts, transitions, or recovers operation in order to prevent damage to equipment, processes, and products.
A machine does not always operate under normal conditions.
In actual operation, situations such as the following may occur:
A device does not respond to a command.
A function is not completed within the allowable time.
Sensor signals contradict one another.
A product becomes jammed or is fed twice.
Motor load increases.
Pressure or temperature leaves the normal range.
Communication is lost.
Electrical power or pneumatic supply is lost.
Mechanical friction or backlash increases.
Product quality exceeds the allowable limits.
Abnormal and Protective Control does more than simply display an alarm.
It must systematically determine:
Which conditions should be classified as abnormal
What range is affected by the abnormality
Whether operation may continue
Whether speed or output should be limited
Which functions should be stopped first
Which outputs must remain active
Whether automatic recovery is possible
Whether operator intervention is required
What must be reverified before restart
The essence of abnormal response and protective control is therefore to design how the machine should behave after an abnormal condition occurs.
2. Position within the Control System
The abnormal-response flow of general machinery can be expressed as follows:
Function Execution → State Recognition → Abnormality Detection → Impact Evaluation → Protective Decision → Protective Action → Recovery → Revalidation
The role of each area is as follows:
Area | Role |
|---|---|
Control Function Execution | Executes the required functions and operations |
State Recognition and Decision | Recognizes the actual machine state and determines whether it is normal |
Abnormal Detection | Detects deviation from normal ranges and state inconsistencies |
Protective Decision | Determines the protection method according to impact and severity |
Protective Action | Performs output restriction, function interruption, stopping, and isolation |
Fault Recovery | Removes the cause of the fault and returns the machine to a known state |
Safety-Related Control | Performs safety functions with priority when personnel or equipment are directly exposed to danger |
Abnormal and Protective Control is positioned between standard function control and safety-related control.
It handles general process and equipment abnormalities, while conditions directly affecting personnel safety should be handled separately by Safety-Related Control.
3. Distinction Between Abnormality, Fault, and Hazard
3.1 Abnormal Condition
An abnormal condition is a state that deviates from normal operating conditions.
Examples:
Pressure drop
Temperature rise
Increased position error
Increased cycle time
Delayed sensor response
An abnormality does not necessarily mean an immediate fault or hazard.
3.2 Fault
A fault is a condition in which the required function cannot be performed correctly or part of the equipment cannot maintain its intended state.
Examples:
Motor does not operate
Sensor wire break
Valve stuck
Brake does not operate
Communication failure
Loss of position information
3.3 Hazardous Condition
A hazardous condition is a state that may cause harm to personnel, equipment, or the surrounding environment.
Examples:
A hazardous axis moves while the guard is open.
A vertical axis may fall.
Access is possible while a rotating element is still moving.
Overpressure may cause component failure.
High-temperature components are exposed.
Abnormalities and faults are handled by protective control, while hazardous conditions must be connected to Safety-Related Control.
4. Definition of Protection Targets
The purpose of protective control varies according to what must be protected.
4.1 Equipment Protection
Prevents damage to the machine and its components.
Examples:
Motor overload prevention
Axis collision prevention
Overtravel prevention
Bearing-overtemperature prevention
Spindle stop when lubrication is insufficient
Drive limitation when torque is exceeded
4.2 Process Protection
Maintains process stability and continuity.
Examples:
Prevention of jam propagation
Prevention of incorrect sequence execution
Preservation of intermediate process states
Prevention of abnormal transfer between upstream and downstream equipment
4.3 Product Protection
Prevents product damage and quality defects.
Examples:
Prevention of excessive clamping force
Overheating prevention
Prevention of duplicate processing
Prevention of incomplete products advancing to the next process
Automatic rejection of defective products
4.4 Control System Protection
Prevents damage to control equipment and information.
Examples:
Transition to a safe default state during communication failure
Monitoring of program errors
Protection of memory and parameters
Data preservation during power abnormalities
Blocking of invalid commands
4.5 Personnel Protection
Prevents hazards to personnel.
This area is related to general protective control, but safety functions requiring defined reliability and compliance should be implemented through Safety-Related Control.
5. Classification of Abnormality Causes
5.1 Signal and Sensor Abnormalities
Sensor wire break
Short circuit
Stuck signal
False detection caused by contamination
Sensor displacement
Abnormal analog value
Communication-data error
5.2 Actuator Abnormalities
Motor fails to start
Servo alarm
Inverter trip
Cylinder does not complete
Valve does not respond
Brake does not operate
Heater output abnormal
5.3 Mechanism Abnormalities
Belt breakage
Chain disengagement
Loose coupling
Gear damage
Guide jamming
Excessive friction
Increased backlash
Axis misalignment
5.4 Process Abnormalities
Product not supplied
Duplicate product
Incorrect product orientation
Positioning failure
Clamping failure
Incomplete processing
Inspection failure
Discharge failure
5.5 Energy-Supply Abnormalities
Voltage drop
Power loss
Insufficient pneumatic pressure
Insufficient hydraulic pressure
Vacuum loss
Insufficient cooling water
Insufficient lubrication
5.6 Communication and System Abnormalities
Network disconnection
Response delay
Missing node
Data mismatch
Controller stop
Program-execution abnormality
Parameter error
5.7 Environmental Abnormalities
Excessive temperature
Moisture
Dust
Cleaning-water ingress
Vibration
Electrical noise
6. Basic Structure of Abnormality Detection
Abnormality detection follows this flow:
Reference Definition → State Monitoring → Deviation Detection → Duration Verification → Cause Classification → Abnormality Confirmation
6.1 Reference Definition
Normal and allowable ranges are established.
Examples:
Normal pressure
Allowable position error
Normal temperature
Maximum motor load
Maximum cycle time
6.2 State Monitoring
Relevant signals and state variables are continuously monitored.
6.3 Deviation Detection
The difference between the target or normal range and the actual value is detected.
6.4 Duration Verification
The system determines whether the condition is a momentary fluctuation or a sustained abnormality.
6.5 Cause Classification
Possible causes are classified as sensor, device, mechanism, or process abnormalities.
6.6 Abnormality Confirmation
When the required conditions and duration are satisfied, the abnormal condition is confirmed and passed to the protective-decision logic.
7. Abnormality Detection Methods
7.1 Threshold Detection
Determines whether a measured value has left the specified range.
Examples:
Temperature exceeds the upper limit.
Pressure falls below the lower limit.
Torque exceeds the upper limit.
Position error exceeds the allowable value.
7.2 Timeout Detection
Detects when a function is not completed within the specified time.
Examples:
Cylinder forward movement not completed
Product arrival delayed
Servo fails to reach position
Communication response delayed
7.3 Command–Response Mismatch Detection
Compares the issued command with the actual device response.
Examples:
No rotation after a motor-start command
No pressure change after a valve-ON command
Brake feedback not confirmed after a brake-release command
7.4 State-Inconsistency Detection
Determines whether related states logically contradict one another.
Examples:
Forward and reverse sensors ON simultaneously
Door Open and Door Closed signals ON simultaneously
Axis-stop state and detected speed occurring simultaneously
7.5 Trend Detection
Uses changing trends to identify early abnormalities.
Examples:
Gradual increase in motor current
Continuous rise in bearing temperature
Increased cycle time
Repeated increase in position error
Increased pneumatic consumption
7.6 Model- or Relationship-Based Detection
Determines whether the relationship between related physical quantities is normal.
Examples:
Heater output increases, but temperature does not rise.
Motor current increases, but the axis does not move.
The valve is closed, but pressure continues to increase.
8. Classification of Abnormality Severity
Not all abnormalities should be handled at the same level.
Level | Meaning | Typical Response |
|---|---|---|
Information | Reference information | Record or display |
Caution | Early abnormality indication | Increased monitoring |
Warning | Possible impact on quality or equipment | Warning or restricted operation |
Fault | Function cannot be completed | Fault stop |
Protective Stop | Possibility of equipment damage | Protective stop |
Safety Critical | Immediate risk to personnel or equipment | Safety stop |
Severity should be determined according to:
Whether the function can still be performed
Impact on product quality
Possibility of equipment damage
Possibility of fault propagation
Recoverability
Risk to personnel
Reliability of the state information
9. Fundamental Principles of Protective Decisions
Protective decisions should be based not merely on the fact that an abnormality occurred, but on what may be endangered by that abnormality.
The following questions should be reviewed:
Can the current function continue?
Is it safer to complete the current cycle?
Is immediate stopping required?
Can only the affected axis or function be stopped?
Can operation continue if pressure, temperature, or load is reduced?
Can the product be discharged safely?
Must the current position be maintained?
Must energy be isolated?
Is automatic recovery possible?
Is operator intervention required?
Protective control should not simply turn off all outputs in the same way for every abnormality.
It should select the minimum safe and reasonable response appropriate to the impact of the abnormality.
10. Types of Protective Actions
10.1 Output Correction
Automatically corrects a small deviation.
Examples:
Speed adjustment
Pressure adjustment
Temperature-output adjustment
Position correction
10.2 Function Restriction
Restricts certain functions or performance.
Examples:
Maximum speed limitation
Torque limitation
Prohibition of certain axes
Automatic operation prohibited
Only low-speed manual operation permitted
10.3 Operation Hold
Temporarily holds the function until the required condition is restored.
Examples:
Wait for downstream equipment to become Ready
Wait for pneumatic pressure to recover
Wait for temperature stabilization
10.4 Automatic Retry
Returns to a safe state and reexecutes the function a limited number of times.
10.5 Local Stop
Stops only the affected function or module.
Examples:
Stop the feeding module
Stop a specific axis
Isolate the inspection module
10.6 Normal Stop
Stops after safely completing the current cycle or process.
10.7 Protective Stop
Stops operation and maintains a protective state to prevent equipment or process damage.
10.8 Safety Stop
Stops according to Safety-Related Control when a direct hazard to personnel or equipment exists.
11. Distinction Between Protective Stop and Safety Stop
Protective stop and safety stop have different purposes and implementation criteria.
Protective Stop
Its primary purpose is to prevent damage to equipment, processes, or products.
Examples:
Motor overload
Insufficient lubrication
Product jam
Excessive position error
Abnormal machining load
It may be implemented using a standard PLC or controller.
Safety Stop
Its primary purpose is to limit risk to personnel or serious hazardous energy.
Examples:
Safety door opening
Light curtain interruption
Emergency stop
Risk of vertical-axis fall
Excessive hazardous speed
A safety stop should be implemented using the required safety architecture, such as a safety PLC, safety relay, or safety drive function.
General protective control must not be treated as a safety function.
12. Evaluation of the Scope of Abnormality Impact
Abnormalities should be handled differently according to their scope of impact.
12.1 Single-Device Abnormality
Limited to a specific sensor, motor, cylinder, or valve.
Response:
Stop the affected device
Isolate the function
Maintain other functions
12.2 Module Abnormality
Affects an entire functional module such as feeding, processing, inspection, or discharge.
Response:
Stop the module
Block upstream and downstream handshakes
Restrict product movement
12.3 Machine-Wide Abnormality
Affects the controller, power supply, pneumatic supply, or safety state.
Response:
Stop the entire machine
Manage energy
Prevent restart
12.4 Line Abnormality
Affects upstream and downstream equipment and the entire production line.
Response:
Stop product transfer
Propagate state information
Perform synchronized line stop
Manage restart sequence
13. Prevention of Abnormality Propagation
An abnormality in one area should not spread to other functions or devices.
Examples:
Prohibit feeding the next product after a discharge failure.
Do not immediately release the clamp after a machining-axis fault.
Stop upstream feeding when downstream equipment stops.
Prohibit uncontrolled execution of pneumatic functions when pressure is insufficient.
Prevent additional products from entering when a jam occurs.
To prevent propagation, the following should be defined:
Functions to block
Functions to maintain
States to transmit to upstream and downstream equipment
Position in which the product should remain
Whether energy should be maintained or removed
Recovery sequence
14. Output Retention and Output Shutdown
Immediately turning every output OFF is not always safe when an abnormality occurs.
Outputs That May Need to Be Maintained
Vertical-axis brake
Product-drop-prevention clamp
Cooling fan
Lubrication pump
Safety-door lock
Vacuum holding
Pressure-holding valve
Outputs That May Need to Be Disabled
Hazardous-axis drive
Additional product feeding
Heating output
Cutting and pressing operation
Abnormal rotating element
Energy supply to the faulted module
Protective actions should therefore clearly define:
Outputs to disable
Outputs to maintain
Outputs to disable after a delay
Outputs to maintain conditionally
Outputs that require manual release
15. Restricted Operation and Degraded Mode
Not every abnormality requires an immediate complete stop.
In some cases, the machine may continue to operate with reduced performance.
Examples of Restricted Operation
Reduced production speed
Certain axes disabled
Manual operation only
Limited product types
Reduced maximum torque
Operator inspection required when automatic inspection is unavailable
Time-limited operation when one of two redundant sensors fails
Restricted operation requires the following conditions:
Is restricted operation safe?
Can product quality still be guaranteed?
Can the operator clearly recognize the condition?
Is a time or production-quantity limit defined?
Is a maintenance request generated automatically?
Is automatic return to normal mode prevented?
16. Design of Automatic Retry
Some abnormalities can be recovered through automatic retry.
Examples:
Product realignment
Cylinder retraction and reextension
Retransmission of a communication command
Restart of a feeding device
Sensor redetection
Automatic retry should define:
Abnormalities for which retry is permitted
Abnormalities for which retry is prohibited
Safe position before retry
Maximum retry count
Waiting time between retries
Restrictions during retry
Stop level after repeated failure
Retry-history recording
Automatic retry should be restricted for:
Functions with possible personnel access
Functions in which repetition increases product damage
High-load pressing or cutting functions
Functions with untrustworthy state information
Functions in which mechanical jamming is suspected
17. Fault Isolation
The failed device or function should be separated from the rest of the system to prevent further impact.
Isolation Targets
Electrical power
Pneumatic supply
Hydraulic supply
Communication
Product movement
Function commands
Upstream and downstream interfaces
Isolation Methods
Output shutdown
Valve closure
Communication-node disable
Transmission of Busy or Fault state
Product-transfer prohibition
Exclusion from function selection
After isolation, state information must be communicated clearly so that other modules do not receive incorrect Ready signals.
18. Diagnosis and Cause Classification
Good protective control does not stop at abnormality detection. It should narrow the range of possible causes.
For example, if a cylinder does not reach the forward-completion position, possible causes include:
Insufficient pneumatic pressure
Valve not operating
Cylinder stuck
Mechanical jam
Sensor failure
Sensor displacement
Product interference
The following information may be used for diagnosis:
Command-output state
Valve feedback
Pressure change
Position sensors
Operating time
Previous-cycle data
Motor or device load
Operator confirmation information
The diagnostic result may be presented as a list of probable causes rather than a single confirmed cause.
19. Alarm Structure
An alarm should not be only a code and message. It should help the operator understand and correct the problem.
Information to Include in an Alarm
Alarm code
Location
Function in which it occurred
Abnormal state
Probable cause
Immediate required action
Recovery condition
Whether restart is permitted
Related device
Time of occurrence
Number of repetitions
Alarm Message Examples
Inadequate:
Cylinder ErrorAlarm 102
Appropriate:
Clamp Cylinder Forward TimeoutRequired action: Check air pressure, product interference, and forward sensorAutomatic operation cannot resume until clamp position is verified
20. Alarm Priority
When multiple alarms occur, the initial cause and subsequent consequences should be distinguished.
Example:
Insufficient pneumatic supply
Clamp forward failure
Machining start prohibited
Cycle-time exceeded
In this case, insufficient pneumatic pressure is the root cause.
Alarm priorities may be organized as follows:
Root Cause Alarm
Primary Fault
Secondary Fault
Process Consequence
Informational Event
If every alarm is displayed at the same level, it becomes difficult for the operator to identify the actual cause.
21. Event and History Logging
To analyze abnormality causes, state information before and after the event should be recorded.
Information to Record
Time of occurrence
Operating mode
Function being executed
Immediately preceding command
Related sensor states
Main analog values
Product information
Recipe
Retry count
Operator action
Recovery time
For important abnormalities, storing data from both before and after the event is effective.
22. Power Loss and Recovery
Power loss may make the machine state uncertain.
After power is restored, the following should be verified:
Can the axis position be trusted?
Has the product position changed?
Were pneumatic or hydraulic states maintained?
Was the clamp maintained?
Is the brake normal?
Can the previous process continue?
Is homing required?
Automatic continuation of the previous operation after power recovery should generally be avoided.
The machine should transition to an Unknown or Recovery Required state and permit operation only after revalidation.
23. Response to Loss of Pneumatic or Hydraulic Supply
Loss of pneumatic or hydraulic pressure may cause a device to move unintentionally.
Items to review:
Does the clamp release?
Does a vertical axis fall?
What is the default state of the valve?
Does residual pressure remain?
Does sudden movement occur when pressure returns?
Must the position be verified before repressurization?
Required protective measures may include:
Check valve
Pilot-operated check valve
Pressure-holding device
Flow restriction
Drop-prevention valve
Restart prevention after pressure recovery
24. Response to Communication Failure
The state each device should maintain during communication failure must be defined.
Items to Review
Should the last command be maintained?
Should the output be turned OFF?
Should the device enter a restricted state?
Should local control continue?
Should a Fault state be transmitted to the supervisory system?
The default behavior during communication failure may differ by device.
Examples:
Conveyor performs a controlled stop.
Clamp remains engaged.
Heater output is limited.
Product feeding stops.
Brake engages.
25. Recovery Stages
Abnormality recovery should preferably proceed through the following stages:
Confirm the abnormality and protective action.
Confirm that hazardous energy has been limited.
Distinguish the root cause from secondary alarms.
Remove the cause of the abnormality.
Check related devices and sensors.
Verify product and tool positions.
Resolve incomplete functions.
Perform homing if required.
Recheck interlocks and protective conditions.
Confirm an intentional operator reset.
Return to the Ready state.
Permit automatic operation only after limited test operation.
Recovery is not simply the process of turning off an alarm bit.
26. Fundamental Principles of Reset
Reset does not remove the cause of an abnormality.
Reset initializes the state only after confirming:
The cause of the abnormality has been removed.
The protective action has ended correctly.
Device positions have been verified.
Safety conditions are satisfied.
The machine is ready for restart.
Reset should not be permitted when:
The abnormal signal is still present.
Position state is uncertain.
The hazardous area is being accessed.
Brake state is uncertain.
Communication recovery has not been confirmed.
The recovery procedure has not been completed.
27. Restart Prevention
A machine must not restart automatically simply because an abnormality has been cleared or power has been restored.
Restart requires:
Intentional operator action
Confirmation of Ready state
Verification of product condition
Verification of device condition
Verification of safety conditions
Confirmation that upstream and downstream equipment are ready
Even if a previous output command remains, it must not execute until the restart conditions are satisfied.
28. Relationship with Control State Recognition and Decision
State Recognition and Decision recognizes and classifies abnormal states.
Abnormal and Protective Control uses those results to determine:
Whether operation should continue
Whether functions should be restricted
Whether retry should be performed
Which devices should stop
Which outputs should remain active
What recovery procedure should be followed
In other words:
State Recognition identifies the abnormality, and Protective Control protects the machine and process from its consequences.
29. Relationship with Control Function Execution
When an abnormality occurs during function execution, Protective Control changes or interrupts the execution.
Examples:
Hold function execution
Prohibit transition to the next step
Cancel the current function
Return to a safe position
Perform automatic retry
Transition to a fault state
Function Execution defines normal behavior, while Protective Control defines behavior when normal execution can no longer continue.
30. Relationship with Interlock Control
Interlocks prevent incorrect operation before an abnormality occurs.
Protective Control responds after an abnormality has already occurred or normal conditions have been lost.
Examples:
Interlock: Prohibit clamp start when pneumatic pressure is insufficient.
Protective control: If pneumatic pressure drops during clamping, stop processing and maintain the clamp state.
Interlock and protective control therefore have a preventive-response relationship.
31. Relationship with Safety-Related Control
When an abnormal state is connected to personnel risk or a serious hazard, Safety-Related Control takes priority.
Examples:
General motor overload: protective stop
Safety guard opens around a rotating element: safety stop
Product jam: function stop
Pressing while an operator enters the area: safety stop
The boundary between protective control and safety-related control should be defined through risk assessment.
32. Interface with Assembly
The performance of protective control depends on the actual assembly condition.
Required Assembly Information
Sensor installation position
Overtravel-stopper position
Brake installation direction
Pressure-switch setting
Torque-limiter setting
Cable and piping connections
Cooling and lubrication piping
Accessibility of protective devices
Inspection points
Installation criteria and inspection methods should be provided so that assembly errors do not lead to protective-control malfunction.
33. Interface with Manufacturing
The same protective decisions and responses must be reproduced on every manufactured machine.
Parameters to Manage
Warning threshold
Stop threshold
Hysteresis
Timeout
Retry count
Limited speed
Torque limit
Pressure limit
Temperature limit
Recovery conditions
Manufacturing and Commissioning Tests
Sensor-fault test
Timeout test
Overload test
Pressure-drop test
Communication-loss test
Power-loss test
Retry test
Protective-stop test
Recovery test
Restart-prevention test
34. Major Design Deliverables
Deliverable | Purpose |
|---|---|
Abnormal Condition List | Defines abnormal conditions |
Fault Classification | Classifies fault types and affected scope |
Severity Matrix | Defines abnormality severity and response level |
Protective Action Matrix | Defines protective actions for each abnormality |
Alarm List | Defines alarm codes, messages, and actions |
Root Cause Matrix | Defines relationships between root causes and secondary abnormalities |
Timeout List | Defines timeout criteria for each function |
Retry List | Defines retry conditions and limits |
Degraded Mode Definition | Defines restricted-operation conditions |
Output Retention Matrix | Defines which outputs are maintained or disabled |
Fault Isolation Diagram | Defines fault-isolation scope |
Recovery Procedure | Defines the recovery sequence after an abnormality |
Restart Permission List | Defines restart-permission conditions |
Fault Test Sheet | Defines testing criteria for abnormalities and protective functions |
Event Logging Specification | Defines abnormal-event logging requirements |
35. Review Questions for Abnormal and Protective Control
Abnormality Definition
Are normal and abnormal ranges defined?
Are abnormality, fault, and hazard distinguished?
Is a timeout defined for every function?
Is command–response mismatch detected?
Severity
Has the scope of impact been evaluated?
Are impacts on product, process, equipment, and personnel distinguished?
Are protective stop and safety stop distinguished?
Is state uncertainty reflected in the severity level?
Protective Action
Are outputs to disable and outputs to maintain defined?
Is local stopping possible?
Can abnormality propagation be prevented?
Are restricted-operation conditions clear?
Retry
Are retry-permitted abnormalities clearly defined?
Are the maximum retry count and waiting time defined?
Is the response after repeated failure defined?
Is retry restricted for hazardous functions?
Recovery
Can the root cause be distinguished from subsequent faults?
Is the actual state reverified before recovery?
Is the need for homing defined?
Are reset and restart conditions distinguished?
Assembly and Manufacturing
Are installation criteria available for protective sensors and devices?
Can thresholds and parameters be reproduced?
Can every protective function be tested?
Are power-loss, communication-loss, and pressure-loss tests included?
36. Conclusion
Abnormal and Protective Control is the control domain that detects abnormalities when the machine deviates from normal conditions, protects equipment, processes, and products according to their impact, and restores the machine to a verifiable state.
Its essence is not to create as many alarms as possible.
The important task is to clearly define:
What should be classified as abnormal
What the abnormality affects
Whether operation may continue
Which functions should be restricted or stopped
Which outputs must remain active
Whether automatic retry is permitted
How the fault should be isolated
How the root cause should be distinguished
How the machine should recover and restart
Good abnormal response and protective control does not simply stop the machine after a fault occurs.
It evaluates the severity and scope of impact, restricts only the necessary functions, and prevents the abnormality from propagating to other devices and processes. It also reverifies the positions of the machine, product, tooling, and energy state after recovery so that operation does not resume in an incorrect condition or the same abnormality does not recur.
This allows Control Function Execution to stop predictably under abnormal conditions, enables Control State Recognition and Decision to provide reliable state information for protective decisions, and allows Safety-Related Control to take priority when an actual hazardous condition occurs.